Steam Generator Electrical Requirements: Amps, Wire and Breaker by Model

Short answer: every residential Mr. Steam and Kohler steam generator we sell runs on 240 volts and needs its own dedicated circuit. Small units draw about 13 to 27 amps; the largest home steam room units draw up to 125 amps. None of them plug into a normal 120V outlet. Your electrician sizes the breaker and wire from the generator's amps, and the tables below give those numbers for each model.

Is there a 120V steam shower generator?

Not among the residential generators we carry. Mr. Steam lists its residential generators at 240V single phase (208V and three-phase versions exist for some models), and Kohler's Invigoration generators are 240V only. A 120V circuit can't supply the 3 to 30 kilowatts these units need to heat water into steam fast enough for a shower. If a listing says "plug-in steam shower", it is usually a small portable unit or a cabin with its own built-in generator; check that cabin's spec sheet for its circuit.

Mr. Steam generators: amps and wire by model (240V, single phase)

Room size is the total adjusted volume after Mr. Steam's material and ceiling adjustments. Use our sizing calculator to get that number first.

Series Model kW Adjusted room size Amps at 240V Min. copper wire Typical breaker*
Steam@Home SAH3000 3 60–75 cu ft (tile) 13 A 12 AWG 20 A
Steam@Home SAH4500 4.5 76–110 cu ft 19 A 8 AWG 25 A
Steam@Home SAH6000 6 111–150 cu ft 25 A 8 AWG 35 A
MS MS90R 5 up to 71 cu ft 21 A 10 AWG 30 A
MS MS150R 6 72–107 cu ft 25 A 8 AWG 35 A
MS MS225R 7.5 108–161 cu ft 32 A 8 AWG 40 A
MS MS400R 9 162–257 cu ft 38 A 8 AWG 50 A
Super MSSuper1R 10 258–339 cu ft 42 A 8 AWG 60 A
Super MSSuper2R 12 340–411 cu ft 50 A 6 AWG 70 A
Super MSSuper3R 15 412–482 cu ft 63 A 4 AWG 80 A
MAX MX4R 20 483–678 cu ft 84 A 2 AWG 110 A
MAX MX5R 24 679–822 cu ft 100 A 1 AWG 125 A
MAX MX6R 30 823–964 cu ft 125 A 2/0 AWG 175 A

*Mr. Steam's documents give amps and minimum wire size and say to install a separate circuit breaker between the supply and the unit. They do not print a breaker size. The breaker column is the typical circuit size used in distributor data; your electrician confirms it under your local code. At 208V the amps are higher (for example, Mr. Steam lists the MS90R at 24 A at 208V).

Kohler Invigoration generators: dedicated circuit by model (240V)

Model kW Max shower size Rated amps Dedicated circuit (Kohler)
K-32324-NA 5 84 cu ft 27 A 240V, 40 A
K-32325-NA 7 112 cu ft 36 A 240V, 50 A
K-32326-NA 9 240 cu ft 45 A 240V, 60 A
K-32327-NA 11 317 cu ft 46 A 240V, 60 A
K-32328-NA 13 447 cu ft 59 A 240V, 80 A
K-32329-NA 15 500 cu ft 68 A 240V, 90 A

Kohler prints the dedicated circuit in its installation instructions, so this column comes straight from the maker.

What your electrician needs to know

  1. The exact model and voltage. Amps change with kW and with 208V vs 240V.
  2. A dedicated circuit. The generator shares its circuit with nothing else.
  3. Panel capacity. A 9 kW generator adds about 38 A of load; a MAX adds 84 to 125 A. Older 100 A panels may need a load calculation or an upgrade.
  4. Distance from the panel. Long runs can need heavier wire than the minimum in the table.
  5. Where the generator goes. Usually a vanity, closet, attic or basement near the shower, within the maker's maximum steam-line length. See our installation guide.
  6. Permits. Many towns require an electrical permit for a new 240V circuit.

Does a steam generator need a GFCI breaker?

Follow the maker's installation instructions and your local code, and let your licensed electrician decide. Check the installation manual for your exact model before you buy a breaker.

How much power does a steam shower use?

The generator only draws full power while it is making steam. As a rough example, a 9 kW unit running for a 20-minute session uses up to about 3 kWh. At the October 2026 US average residential price of about 18 cents per kWh (EIA), that is roughly 50 cents a session at most. Your rate and session length will change this.

Quick answers

Can I run a steam generator on a 30 amp circuit?

Only the smallest models fit: Mr. Steam's MS90R (21 A, typically a 30 A circuit) and Steam@Home SAH3000 (13 A). Larger models need a bigger dedicated circuit.

Do I need a licensed electrician?

Yes. Both Mr. Steam and Kohler call for installation by qualified trades, and a new 240V circuit usually needs a permit.

Which generator size do I need?

That depends on your shower's volume and wall materials, not just its floor area. Use the sizing calculator, then match the model to the tables above.

Sources

  • Mr. Steam installation, operation and maintenance manual, MS90R–MS400R and MSSUPER1R–3R, PUR 100597A Rev 8.25.
  • Mr. Steam installation, operation and maintenance manual, MAX MX4R–MX6R, PUR 100598A Rev 8.25.
  • Mr. Steam installation, operation and maintenance manual, Steam@Home, PUR 100622 Rev 5.25; spec sheet TS0106 Rev 5.25.
  • Mr. Steam technical spec sheets TS0041 Rev 6.25 (MS) and TS0080 Rev 5.25 (MAX).
  • Kohler installation instructions, Steam Generator 5–11 kW, 1601844-2-B, and 13–15 kW, 1601845-2.
  • US Energy Information Administration, Short-Term Energy Outlook, October 2026, Table 7c.

How we write our guides: every number comes from the manufacturer's current manuals and spec sheets listed above. Updated November 2026.

Next article How to Install a Steam Shower: What Your Electrician and Plumber Need

Compare products

Select 2 or 3 items to compare

Select first item to compare

Select second item to compare

Select third item to compare

Compare